RS_No | IMO | Name | Flag | Type of vessel | Class status | Recommendations | Type |
---|---|---|---|---|---|---|---|
040169 | 9333577 | GENERAL HAZI ASLANOV | ![]() |
Oil tanker/Chemical tanker | CLASS SUSPENDED | Due to detention, the ship shall be carried out to occasional survey before departure, but not later than 03.12.2020 | Class |
040239 | 9353917 | SEVERINA | ![]() |
Pleasure yacht | CLASS SUSPENDED | The newly installed equipment AIS should be included in the Ship Station Licence till 06.12.2020 . | Class |
070130 | 9435337 | KURA RIVER | ![]() |
Oil tanker/Chemical tanker | CLASS VALID | EFP shaft gland seal leakage should be eliminated. | Class |
070130 | 9435337 | KURA RIVER | ![]() |
Oil tanker/Chemical tanker | CLASS VALID | Workability of control means of fire-damper of galley exhaust duct should be restored. | Class |
070130 | 9435337 | KURA RIVER | ![]() |
Oil tanker/Chemical tanker | CLASS VALID | Workability of remote roller drives of ballast pumps and EFP inlet valve should be restored (S,P, frs.83-85). | Class |
080397 | 9562178 | DENIS VETCHINOV | ![]() |
RoRo cargo/General cargo | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey by 10.01.2021 in scope of annual one shall be carried out according to item 4.8.3.1, Part II "Survey Schedule and Scope" of the Rules for the Classification Surveys of Ships in Service". After completion of the survey a new term of the requirement shall be imposed. | Class |
101644 | 9631929 | VIKTOR | ![]() |
General cargo | CLASS SUSPENDED | The diesel engine of Auxiliary diesel generator No. 3 should be repaired/renewed according to technology approved by RS and under RS technical supervision not later than 31.12.2020. The Auxiliary diesel generator No. 3 should be tested in operation after repair/renewal. | Statutory |
101644 | 9631929 | VIKTOR | ![]() |
General cargo | CLASS SUSPENDED | The port side Main Engine should be repaired and checked in operational condition on the ship not later than 15.01.2021. | Statutory |
111679 | 9619517 | MS.YVONNE | ![]() |
Tender | CLASS SUSPENDED | Main Engines No.1, 2, 3, 4 and Auxiliary Engines No.1, 2 to be submitted in operation after completion of the maintenance. | Class |
130609 | 9729594 | MILAGRESS | ![]() |
Oil tanker/Chemical tanker | CLASS VALID, THE SHIP IS UNDER SURVEY | The permanent repair of the ship's fender (P, C) should be carried out and submitted to RS. | Class |
140263 | 9758179 | BUMI NARYAN-MAR | ![]() |
Supply vessel (ORSV) | CLASS VALID | Perform a check of 7 pcs. life rafts. | Statutory |
150975 | 9774501 | ULTRACARGA IV | ![]() |
Passenger/RoRo cargo | CLASS SUSPENDED | Occasional survey of the vessel due to change of two Main Engines to be carried out not later than 01.09.2020 | Class |
160106 | 9802762 | MAAIKE | ![]() |
Oil tanker | CLASS SUSPENDED | The ship is to be fitted with an approved by RS Stability instrument in accordance with MARPOL Annex I, reg. 28. | Statutory |
160106 | 9802762 | MAAIKE | ![]() |
Oil tanker | CLASS SUSPENDED | The ship is to be submitted to occasional survey for the purpose of confirmation of providing with prompt access to computerised shore-based damage stability and residual structural strength calculation programsin accordance with requirements of MARPOL Annex I reg. 37.4. | Statutory |
591540 | 5142750 | EVANGELIYA | ![]() |
Hostel | CLASS VALID | The Ship should be with Long-Range Identification and Tracking System not later than 03.04.2014 (see letter of the Kazakhstan Maritime Administration № 04-13/33545 от 23.12.2013). | Statutory |
682398 | 8927864 | VIKTOR MUHORTOV | ![]() |
Tug | CLASS SUSPENDED | The Calculation of Tonnage is to be submitted in accordance with the current RS Rules. | Class |
704205 | 8949367 | SOBRAY | ![]() |
General cargo | CLASS SUSPENDED | Until 18.08.2020, it is necessary to renew the structures and equipment of the ship's superstructure damaged by fire | Class |
720212 | 7330038 | ERMAK | ![]() |
Icebreaker | CLASS SUSPENDED | Perform a visual inspection and defect of the welded joints of the hull of the ship in the dock with the subsequent repair. | Class |
724336 | 7212248 | VITYAZ | ![]() |
Fishing | CLASS SUSPENDED | Log should be presented in operation. | Class |
734450 | 7379553 | NADEZHDA | ![]() |
Refrigerated cargo ship | CLASS VALID | The technical documentation on installation of VHF radio installation, two sets, type of STR-6000A, approved by RS should be submitted. | Statutory |
752228 | 8899782 | DVINA | ![]() |
Oil tanker | CLASS SUSPENDED | Main mast deck plating and galley deck plating to be properly repaired. | Class |
752228 | 8899782 | DVINA | ![]() |
Oil tanker | CLASS SUSPENDED | Thorough repair of fire pump foundation in ER to be carried out. | Class |
752228 | 8899782 | DVINA | ![]() |
Oil tanker | CLASS SUSPENDED | Thorough repair of windlass foundation to be carried out. | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Add missing bolts on air pipe flanges | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Align the cable lines with the applicable requirements of the RS Rules | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Bring the protective pipelines of the cable routes on the upper bridge into compliance with the applicable requirements of the RS Rules | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Bring the sampling device of the bilge water separator in accordance with MARPOL 73-78 | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Close the throat in the forepeak | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Dispose of screw backs of cargo hold covers | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Submit documents confirming that thorough inspection and maintenance of lifeboat launching devices has been carried out, including dynamic load testing of winch brakes | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Submit the act of installing flexible connections of the CO2 cylinders fire extinguishing system | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Update ITU publications List IV and List V | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Сlean up in M.O., remove all foreign objects | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Show the operation of the sound signal of the charger when switching the power supply of the equipment GMDSS for backup source | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Submit a certificate for flexible connections of a CO2 volumetric fire extinguishing system | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Submit a foam concentrate test report | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Submit a plan for maintenance, repair and inspection of fire fighting systems and equipment | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Submit bunker invoices with fuel samples | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Submit documentary evidence of replacement of lifeboat launching devices Lapps | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Replace worn out mooring lines | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Restore the bulkheads of the wheelhouses in the area of ??the passage of cables for television antennas and air conditioners | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Restore the roller of the bale bar on the tank | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Restore the tightness of the bulkhead of the aft superstructure, in the area of ??the boatswain's storeroom on the PS | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Restore the tightness of the engine room mine along the P.S., in the area of ??the QRV drives | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Restore the ventil on the cut-off valve of the water-fire system, present the valve in operation | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair two balusters of the access ladder to the tank along the PS | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair ventilation hatches ADG | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Replace homemade stern light | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Replace non-standard flexible joints in a category "A" room with metal ones | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Replace rubber seals on rectangular ventilation pipes | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Replace self-rescuers | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair similar hatches in the corridors of double sides along the PS and St S, in the aft part of the cargo hold | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair the boat deck according to P.S. | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair the bulb | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair the door to the boatswain's storeroom on the PS. | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair the guides for lowering the boat along the P.S. | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair the ventilation pipe in the area of ??the ladder along SB | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Present the supply of lifeboats | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Provide confirmation of registration of the ARB in the ICVC | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Provide emergency lighting and lighting of outboard spaces in work | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Remove the cables passing through the hatch coaming to the thruster room on the tank | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair doors in bulwarks on PS and Avenue SB. | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Repair safety devices on davit mechanisms | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Paint niches of side lights with matte paint | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Present boarding ramps | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Present explosion-proof lanterns and radios in firefighter equipment kits | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Present fire alarm at work | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Present fuel leakage system in operation | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Present in operation a gyrocompass with repeaters | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Eliminate oil and fuel leaks of oil and fuel pumps | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Fix a flooring of decks of E.R. | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Install garbage bins according to the Ship's Garbage Management Plan | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Install the side light on the PS | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Install the standard parts on the hinged stoppers of the anchor chains | Class |
775198 | 7707712 | FORTUNA | ![]() |
General cargo | CLASS SUSPENDED | Mark the flanges of the oil residues and wastewater discharge pipelines, install the missing flange fasteners | Class |
792367 | 7831812 | BAZHENOVSK | ![]() |
Fishing | CLASS SUSPENDED | Permanent repair of the forecastle deck steel plating near the hatch coaming of the cargo hold No.1 in the area of frs. 17-23 is to be carried out. | Class |
792367 | 7831812 | BAZHENOVSK | ![]() |
Fishing | CLASS SUSPENDED | Permanent repair of the side and bulkhead construction in the area of frs. 134-136 at the net store and switchboard room, starboard on lower deck level is to be carried out. | Class |
792367 | 7831812 | BAZHENOVSK | ![]() |
Fishing | CLASS SUSPENDED | Permanent repair of the starboard side framing in the area of frs. 87-89 at the engine room on double bottom level is to be carried out. | Class |
793035 | 7741160 | RIGEL | ![]() |
Ore/Oil carrier | CLASS SUSPENDED | Repair the damaged middle rudder of the vessel when the vessel is docked | Class |
794220 | 8926913 | AKCA 1 | ![]() |
General cargo | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II "Survey Schedule and Scope" of the Rules for the Classification Surveys of Ships in Service. After completion of the survey a new term of the requirement shall be imposed. | Class |
821343 | 8138891 | NEREY | ![]() |
Fishing | CLASS SUSPENDED | 18.01246.150_002_Install the watertight door (fr.18, SB) in tambour of gangway from the main deck to the platform deck before reactivation survey. | Class |
821343 | 8138891 | NEREY | ![]() |
Fishing | CLASS SUSPENDED | After equipped of the ship by fish-processing workshop the ship should be provided with Fire Plan. | Class |
821343 | 8138891 | NEREY | ![]() |
Fishing | CLASS SUSPENDED | Present to the RS approved technical documentation for the doorway to the tambour i.w.o. of watertight transverse bulkhead fr.14, SB (platform deck) before reactivation survey. | Class |
830022 | 8726155 | NEFTERUDOVOZ-50M | ![]() |
Ore/Oil carrier | CLASS SUSPENDED | Perform a permanent repair of the upper deck floor of the navigation bridge under the RS technical supervision. | Class |
830022 | 8726155 | NEFTERUDOVOZ-50M | ![]() |
Ore/Oil carrier | CLASS SUSPENDED | Speed and distance measurement device should be dismantled or repaired. | Class |
830022 | 8726155 | NEFTERUDOVOZ-50M | ![]() |
Ore/Oil carrier | CLASS SUSPENDED | To submit the ship for PSC deficienses fullfillment not later 01.08.2020 (see letter No. 141-351-10.1-179188 dd 24.07.2020). | Class |
830855 | 8207173 | MPK-459 | ![]() |
Passenger unberthed | CLASS SUSPENDED | To present approved RS technical documentation for the installation of diesel generators. | Class |
831487 | 8228373 | ZVEZDA MORYAKA | ![]() |
Fishing | CLASS SUSPENDED | To perform thorough repair the lower section of aft the bulkhead of the wheelhouse in the area frs. 16-17 P. | Class |
831487 | 8228373 | ZVEZDA MORYAKA | ![]() |
Fishing | CLASS SUSPENDED | To perform thorough repair: the section of the main deck in area frs. 3 – 4 S (forepeak). | Class |
831487 | 8228373 | ZVEZDA MORYAKA | ![]() |
Fishing | CLASS SUSPENDED | To perform thorough repair: the section of the upper deck in area frs. 2 - 3 C. | Class |
831487 | 8228373 | ZVEZDA MORYAKA | ![]() |
Fishing | CLASS SUSPENDED | To perform thorough repair: the section upper deck in area 32-44 fr. P, 52-56 fr. P, 54-56 fr. S and section of the coaming elevation of the main deck in area 32 - 35 fr. P. | Class |
831487 | 8228373 | ZVEZDA MORYAKA | ![]() |
Fishing | CLASS SUSPENDED | To perform thorough repair: the sections of the main deck in area frs. 3 – 4 S, 27 – 28 S and 31 – 33 S (engine room). | Class |
831487 | 8228373 | ZVEZDA MORYAKA | ![]() |
Fishing | CLASS SUSPENDED | Тhe permanent repair of the shell plating with build-up area to be carried out (PS, 32-38 frs). | Class |
831487 | 8228373 | ZVEZDA MORYAKA | ![]() |
Fishing | CLASS SUSPENDED | Тhe underwater area of shell plating with doubler (8x310x400 mm) should be repaired permanent (0-5 frs, PS). | Class |
836048 | 8841450 | ANNENKOV | ![]() |
RoRo cargo | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II “Survey Schedule and Scope” of the Rules for the Classification Surveys of Ships in Service”. After completion of the survey a new term of the requirement shall be imposed. | Class |
836601 | 8216722 | FORLINE I | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | In accordance with ultrasonic thickness measuremnt report No. 122.00328.122UTM dd. 06.10.2020 it is required to perform repair/renew shell plating in following areas: - Plate J3/H3.1, Fr.39-40, 400x400x12.5, STB - Plate J4/H4, Fr.43-47, 3000x600x12.5, STB - Plate J5, Fr.59-61, 1600x400x12.5, STB - Plate J6/H6, Fr.69-79, 6300x500x12.0, STB - Plate J9, Fr.102-104, 1600x400x12.5, STB - Plate I1/S1, Fr.3-8, 2600x600x9.0/11.0, PS - Plate J9/H9, Fr.107-112, 3500x600x12.5, STB - Plate H11, Fr.130-132, 600x700x13.0, STB - Plate I4/H4, Fr.52-53, 1200x600x12.5, PS - Plate J6/H6, Fr.67-73, 5900x600x12.0, PS - Plate J8/H8, Fr.96-97, 900x600x12.0, PS Repair shall be done in p. Las Palmas, Spain, in minimal safe ballast condition, during current special survey of the ship under supervision of the accepting class society. (Ref. RS HO int. doc. No.253895 (20-236328) от 06/10/2020) | Class |
836601 | 8216722 | FORLINE I | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | It is required to perform fault detection and repair of frames in the repair areas of side shell plating in areas: - Plate J3/H3.1, Fr.39-40, 400x400x12.5, STB - Plate J4/H4, Fr.43-47, 3000x600x12.5, STB - Plate J5, Fr.59-61, 1600x400x12.5, STB - Plate J6/H6, Fr.69-79, 6300x500x12.0, STB - Plate J9, Fr.102-104, 1600x400x12.5, STB - Plate I1/S1, Fr.3-8, 2600x600x9.0/11.0, PS - Plate J9/H9, Fr.107-112, 3500x600x12.5, STB - Plate H11, Fr.130-132, 600x700x13.0, STB - Plate I4/H4, Fr.52-53, 1200x600x12.5, PS - Plate J6/H6, Fr.67-73, 5900x600x12.0, PS - Plate J8/H8, Fr.96-97, 900x600x12.0, PS | Class |
836601 | 8216722 | FORLINE I | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Requiremnts, indicated in the Record book of the technical supervision of the vessel during repair No. 20.00326.122 dated 10.09.2020 shall be completed upon end of special survey. 1. Glass plafonds of the emergency lighting system. Plafonds shall be installed, presented in operation. 2. Fauld detection and repair of the gangway from 1-Tier to Upper deck, StB, shall be carried out 3. Faul detection and repair of the hatch coaming of the Cargo Hold Nos. 1-4 shall be carried out. Hydraulic oil leakges shall be removed, hydraulic system piping shall be fixed. 4. Leakages found in Engine room. Repair of the piping of the main fire water, ballast, brine systems shall be carried out. 5. Repair of the cable trays shall be carried out in full lenght of Upper deck Fwd-Aft , PS. 6. repair of the hydrophone No.1 shall be carried out. 7. Oil mist detection system at Main Engine shall be restored. 8. Fault detection and repair of the signal mast shall be carried out. 9. Through corrosion of the bulwark racks and Superstructure bulkheads at Forecastle deck, PS and StB was found. Fault detection and repair shall be carried out. 10. Faul detection and repair of the ventilation heads at Navigation Bridge deck PS and StB shall be carried out. 11. Refrigerating compressors -2 (pcs) type BCR-200MB out of service. Shall be repaired and submitted in operation. 12. Repair of the Upper Deck plating shall be carried out on the ground of performed fault detection on 11.09.2020 (frs.37-43; frs.65-97). 13. Repair of the Navigation Mast Deck, Navigation Bridge Deck, Boat Deck plating with elimination of reinforcement sheets (doublers) shall be carried out on the ground of performed fault detection on 11.09.2020 (frs.2-33). 14. Repair of the Upper Deck plating (frs.134-137, CL) and Cargo hold hatches with coaming Nos.1-4 shall be carried out on the ground of performed fault detection on 14.09.2020. 15. Repair of the Forecastle Deck plating with with elimination of reinforcement sheets (doublers) shall be carried out on the ground of performed fault detection on 15.09.2020 (frs.-8-38). | Class |
836601 | 8216722 | FORLINE I | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Thorough examination and thickness measurements of life-saving launching appliances structures PS and StB shall be included in the scope of survey of upper part of the vessel | Class |
836601 | 8216722 | FORLINE I | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Ultrasonic thickness measurements of seatings of main and auxiluary machineries, boilers shall be performed during special survey under supervision of accepting classification society. | Class |
836601 | 8216722 | FORLINE I | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Ultrasonic thickness measurements of the upper part of the vessel shall be carried out in a scope of Special survey | Class |
836832 | 8320834 | ODIN | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Diesel generator No. 3 to be submited in operation. | Class |
836832 | 8320834 | ODIN | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II “Survey Schedule and Scope” of the Rules for the Classification Surveys of Ships in Service”. After completion of the survey a new term of the requirement shall be imposed. | Class |
840293 | 8729810 | SEVMORPUT | ![]() |
Container ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The ship should be occasional survey in connection with the accident. | Class |
846478 | 8723361 | SORAKSAN | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The ship shall be equipped with technical documentation, approved by RS for NAVTEX receiver installation. | Class |
846798 | 8632847 | SANSHIRO MARU | ![]() |
Fishing | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II “Survey Schedule and Scope” of the Rules for the Classification Surveys of Ships in Service”. After completion of the survey a new term of the requirement shall be imposed | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Agreement for shore maintenance concluded with the Manufacturer of the GMDSS radio equipment or with an enterprise authorized by the Manufacturer to do so, possessing the certificate of recognition by the Register should be submitted before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Compressors of ship's refrigerating plant Nо. 1, 3, 4 should be submitted in operation before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Conditioning system of main machinery control room should be submitted in operation before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | GMDSS radio equipment and AIS should be tested by RS recognized company and submitted in operation before the ship departure | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Limit switch for lifting of the boat should be submitted in operation before the ship departure | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Repair of the fuel leakage collection system of the ME (the system is not connected to the fuel leakage collection tank and there are rubber connections on clamps) should be done before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Searchlights of rescue boats should be submitted in operation before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The brake of the rescue boat's launching device should be presented in operation before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The hook release device of the rescue boat should be carried out an annual survey by organization holding manufacturer's authorization before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The rescue boat should be marked in accordance with the RS rules before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The ship should be provided with life jacket before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | To perform repair the gangway before the ship departure. | Statutory |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Ballast tanks (BT_DEEP_C, BT_F_C) should be examined annually before the ship departure. | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Compressors of ship's refrigerating plant Nо. 1, 3, 4 should be submitted in operation before the ship departure. | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Conditioning system of main machinery control room should be submitted in operation before the ship departure. | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Documents should be submitted of the replacement of hull structures with zones of substantial corrosion under the RS technical supervision before the ship departure. | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Electrical measuring device should be repaired and tested before the ship departure. | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | Repair of the fuel leakage collection system of the ME (the system is not connected to the fuel leakage collection tank and there are rubber connections on clamps) should be done before the ship departure. | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The results of flaw detection should be provided of the bulb's bow plating (fr.115 – bow). Based on the results of flaw detection of damaged structures, the thorough repair should be done in the scope and technology approved by RS before the ship departure.. | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The ship should be equipped with breathing apparatus in accordance with the applicable requirements of the RS Rules before the ship departure | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | The ship should be equipped with portable safe lantern of fireman's outfit before the ship departure | Class |
847593 | 8408258 | ANTARES | ![]() |
Refrigerated cargo ship | CLASS VALID, THE SHIP IS UNDER SURVEY | To perform thorough repair: the section of the captain's deck in the area of the installed doubler (frs 5-6 P) before the ship departure.. | Class |
850346 | 8422242 | YASNYY | ![]() |
Supply ship (ORSV) | CLASS VALID, THE SHIP IS UNDER SURVEY | The repair of portions of the main, intermediate frames and vertical stiffeners of longitudinal bulkheads should be carried out in the ballast tanks No. 23 StB, No. 24 PS, No. 24 StB, No. 26 StB in accordance with approved RS technology in areas, given in enclosure to the RS form 6.3.48r No. 19.10149.121 dd 17.06.2019, within next special survey but not later than 08.09.2020. | Class |
850435 | 8724559 | KAPITAN BELOMESTNOV | ![]() |
Tug | CLASS SUSPENDED | On arrival to the item. Providences, Russia, but in time not later 30.12.2020 the vessel has to be shown to PC to extraordinary survey for preservation of the class RS. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II “Survey Schedule and Scope” of the Rules for the Classification Surveys of Ships in Service”. After completion of the survey a new term of the requirement shall be imposed. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Present in action a set of VHF equipment for two-way radiotelephone communication no later than 28.10.2020. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Present the activation of the ME P and S emergency warning alarm and protections no later than 28.10.2020. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Present the automatic identification system in operation no later than 28.10.2020. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Present the daylight signaling lamp in operation from the main source and from the emergency power source no later than 28.10.2020. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Present the public address system in operation no later than 28.10.2020. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Replace flexible connections. Present the activation of the DG emergency warning alarm and protections no later than 28.10.2020. | Class |
850690 | 8929288 | AKVALOO | ![]() |
Passenger unberthed | CLASS SUSPENDED | Submit serviceable portable dry powder fire extinguishers no later than 10.28.2020. | Class |
851156 | 8406705 | YURIY ARSHENEVSKIY | ![]() |
RoRo cargo/General cargo | CLASS VALID, THE SHIP IS UNDER SURVEY | Item No. 126 of Continuous Survey List Pitch Change Mechanism of controllable pitch propeller should be submitted for survey in disassembled condition. (See RS report № 18.02416.190 dd 01.03.2018). | Class |
851866 | 8721143 | SEAWIND-1 | ![]() |
Fishing | CLASS SUSPENDED | An occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II “Survey Schedule and Scope” of the Rules for the Classification Surveys of Ships in Service”. After completion of the survey a new term of the requirement shall be imposed. | Class |
851866 | 8721143 | SEAWIND-1 | ![]() |
Fishing | CLASS SUSPENDED | Side framing in the fish meal plant compartment PS, SB is to be thoroughly repaired (renewed) at nearest survey in dry dock. | Class |
853594 | 8620026 | STK-1020 | ![]() |
General cargo | CLASS SUSPENDED | Repair of the hull structures 101 fr, PS at the welding area of the frame to the hold hull at the areaof the upper platform. | Class |
855922 | 8417625 | POLARIS-2 | ![]() |
General cargo/Livestock | CLASS VALID, THE SHIP IS UNDER SURVEY | Until 02.01.2021 provide inspection and hydraulic test the pipelines of the carbon dioxide fire extinguishing system. | Class |
867070 | 8311883 | ODEEP ONE | ![]() |
Passenger/RoRo cargo | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II "Survey Schedule and Scope" of the Rules for the Classification Surveys of Ships in Service. After completion of the survey a new term of the requirement shall be imposed. | Class |
867070 | 8311883 | ODEEP ONE | ![]() |
Passenger/RoRo cargo | CLASS SUSPENDED | The Heavy fuel separators and heaters (Continuous survey list points 285, 286, 287, 288, 289, 290, 291, 292, 293) should be presented in operation. | Class |
867070 | 8311883 | ODEEP ONE | ![]() |
Passenger/RoRo cargo | CLASS SUSPENDED | The M.E.№4 should be repaired and presented in operation according to the approved program under RS technical supervision. | Class |
867070 | 8311883 | ODEEP ONE | ![]() |
Passenger/RoRo cargo | CLASS SUSPENDED | The remote control and automation system of M.E. No.4. should be present at work. | Class |
871959 | 8726662 | SPP-19 | ![]() |
General cargo/Hulk | CLASS SUSPENDED | At the end of the race, present the vessel for an occasional survey to preserve the class | Class |
875502 | 8607139 | NIKOLAY TELENKOV | ![]() |
Fishing | CLASS VALID | The ship to be submitted for an occasional survey in order to check the availability of SEEMP Part II and "Confirmation of Compliance" | Statutory |
876695 | 8881711 | OMSKIY-134 | ![]() |
General cargo | CLASS VALID, THE SHIP IS UNDER SURVEY | Shell plating in area 138 fr., on SB and PS should be permanent repaired | Class |
876695 | 8881711 | OMSKIY-134 | ![]() |
General cargo | CLASS VALID, THE SHIP IS UNDER SURVEY | The light signals of the main engine critical parameters on the navigating bridge alarm system panel and the light signals (30 pcs.) on the auxilary engines alarm system panel to be presented at work. | Class |
877283 | 8619560 | BRATTEGG | ![]() |
Fishing | CLASS SUSPENDED | 1. Fault detection and examination by RS of the Main Engine is to be carried out, results of the measurements and flaw detection of the main parts and units are to be submitted. | Class |
877283 | 8619560 | BRATTEGG | ![]() |
Fishing | CLASS SUSPENDED | 2. Change or repair of the Main Engine with the replacement or restoring of defective components under the RS supervision and in accordance with technology, agreed by RS. In case of replacement of the Main Engine, all works shall be carried out in accordance with the documentation approved by the RS. | Class |
877283 | 8619560 | BRATTEGG | ![]() |
Fishing | CLASS SUSPENDED | 3. The RS Certificates for renewed components in accordance with Nomenclature of Items of the Register Technical Supervision are to be submitted. In case Main Engine replacement, RS certificate, technical files and EIAPP certificate for the new engine to be submitted. | Class |
877283 | 8619560 | BRATTEGG | ![]() |
Fishing | CLASS SUSPENDED | 4. After the completion of the repairing or change the Main Engine is to be submitted in operation on mooring and sea trails. | Class |
886278 | 8711253 | IGOR ILINSKIY | ![]() |
General cargo | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II "Survey Schedule and Scope" of the Rules for the Classification Surveys of Ships in Service". After completion of the survey a new term of the requirement shall be imposed. | Class |
887853 | 8821515 | SOKOL | ![]() |
Fishing | CLASS SUSPENDED | A Thorough repair of the upper deck plating in way frs.50-59, S is to be presented to RS upon arrival in ballast condition to the new repair base in the port of Busan (South Korea). RS letter No. 172-C-380311 dated 27.12.2019. | Class |
887853 | 8821515 | SOKOL | ![]() |
Fishing | CLASS SUSPENDED | Postponement of installation of CO2 volumetric fire extinguishing system in a paint room under the following conditions: 1. Complete thorough repair of the above-mentioned object of technical RS supervision by arrival of the vessel by ballast passage to the new repair base in the port of Busan, Korea; 2. Perform of conservation of the paint room, without the presence of flammable materials inside this room, during the passage of the ship in ballast to the new repair base in the port of Busan, Korea. Ground: RS Letter No.122-341-10-201005 dd. 18.08.2020. | Class |
887853 | 8821515 | SOKOL | ![]() |
Fishing | CLASS SUSPENDED | Temporary repair. A removable plating of 360x360x8 mm is installed on the upper deck in the processing shop room, frs.54-55, 250 mm from the longitudinal wall of the processing shop. The Thorough repair of the above-mentioned area of the deck plating shall be presented to the RS upon arrival in ballast condition to the new repair base in the port of Busan (South Korea). The RS Letter No. 122-341-3-41565 dd.19.02.2020. | Class |
887853 | 8821515 | SOKOL | ![]() |
Fishing | CLASS SUSPENDED | Temporary repair. Shell plating. Doublers plates (diameter 200 mm, thickness 25 mm) that are insert plates of the discharge holes from the upper deck scupper, P / S, fr.49. The Thorough repair of the above-mentioned areas of the side shell shall be presented to the RS upon arrival in ballast condition to the new repair base in the port of Busan (South Korea). The RS Letter No. 122-341-3-45153 dd. 24.02.2020. | Class |
887853 | 8821515 | SOKOL | ![]() |
Fishing | CLASS SUSPENDED | Temporary repair: Transverse bulkhead of the hydraulic room of the fishing winch on the upper deck in way S, fr.70 (the bulkhead has a hole, cut out in the way of the passage of hydraulic pipes), a cement box is installed. The hydraulic room was sealing at the period of the ship's passage. The Thorough repair of the above-mentioned area of the transverse bulkhead of the hydraulic room shall be presented to the RS upon arrival in ballast condition to the new repair base in the port of Busan (South Korea). The RS Letter No.122-341-3-164123 от 08.07.2020. | Class |
887853 | 8821515 | SOKOL | ![]() |
Fishing | CLASS SUSPENDED | Temporary repair: - Side plating, PS in way frs.48-53, captain's flaps on the upper deck, 2 pieces, instead of which there are insertions, see the scheme page 230 of the Report No. 20.00037.122 UTM. - The longitudinal wall of the processing shop on the upper deck, S, in way frs.48-49, discharge from the premises of the processing shop, the cement box is installed. - Sealing of the fish shop premises at the period of the ship's passage. The Thorough repair of the above-mentioned areas of the side shell and the discharge shall be presented to the RS upon arrival in ballast condition to the new repair base in the port of Busan (South Korea). The RS letter No. 122-341-10-711 dd. 08.01.2020. | Class |
890606 | 8826759 | TAVRIA | ![]() |
Refrigerated cargo ship | CLASS VALID (FORCE MAJEURE) | Carbon-dioxide fire-extinguishing system for cargo holds should be submitted to external examination. | Class |
893784 | 8832112 | TRONDHEIM | ![]() |
Fishing | CLASS VALID, THE SHIP IS UNDER SURVEY | PS ME repair is to be carried out under RS supervision. | Class |
893784 | 8832112 | TRONDHEIM | ![]() |
Fishing | CLASS VALID, THE SHIP IS UNDER SURVEY | The through repair of the structures with doubling plates in way of trawl deck (fr. 129-133, 2-nd strake from StB; fr. 110-111, 2-nd strake from PS) and 1-st tier of forecastle deck (fr. 18-22, 2-nd strake from StB; fr. 63-65, 1-st strake from PS and 1-st strake from StB), is to be carried out not later than the nearest Special Survey, i.e. 11.01.2021. | Class |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | Daylight signalling lamp should be submit in operation from the main and emergency sources with three spare lamps. | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | IMO signs should be install according to the fire plan. | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | Incinerator with alarms and protection should be submitted in operation | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | Main and emergency lighting should be restore in living quarters, engine rooms, pump rooms and on the open deck, at landing sites in life-saving appliances | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | Registration conformation of EPIRB (Thrane & Thrane AS, SE406-II, № 100-79269) into CMCC should be on a board ship. | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | Sewage water system should be equipped by standard discharge connection. | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | The checking of the possibility to promptly provide all liferafts when released for evacuation with the radio equipment specified in 10.3.2.2, Part I-A of the Polar Code (radar transponder or AIS-SART) should be carried out. The number of above-mentioned devices shall be sufficient for provision of each liferaft. (Refer to 10.2.2.2 and 10.3.2.2, Part I-A of the Polar Code). | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | Up-to-date copy of Volume III of the International Aeronautical and Maritime Search and Rescue (IAMSAR) Manual should be on a board ship. | Statutory |
893799 | 8834691 | PROFESSOR LOGACHEV | ![]() |
Research | CLASS VALID, THE SHIP IS UNDER SURVEY | Up-to-date ITU publications ( List of Coast Stations (List IV) и List of Ship Stations (List V)) should be on a board ship. | Statutory |
896161 | 9019511 | KRATER | ![]() |
Fishing | CLASS SUSPENDED | The technical documentation on installation of AIS equipment approved by RS should be submitted. | Class |
897554 | 8812801 | PACIFICA | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Auxiliary diesel generator No.1 should be submitted in operation with safety alarms and protection. | Class |
897554 | 8812801 | PACIFICA | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Compressor of refrigeration unit No. 3 to be submitted to a survey. | Class |
897554 | 8812801 | PACIFICA | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Hatch on the Forecastle Deck is to be complied with IACS UR S26. | Class |
897554 | 8812801 | PACIFICA | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Perform a complete repair of the side wall of deck-house in the areas of the established duplicating sheets, frs. 86-88 StB. | Class |
897554 | 8812801 | PACIFICA | ![]() |
Refrigerated cargo ship | CLASS SUSPENDED | Poop deck portion around the ER hatch affected by local pittings and temporarily reinforced by fitting of doubling plate is to be re-examined and thoroughly repaired (the requirement contained in BV survey status). | Class |
902659 | 8842612 | KAPITAN SUPRUN | ![]() |
Passenger unberthed | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II “Survey Schedule and Scope” of the Rules for the Classification Surveys of Ships in Service”. After completion of the survey a new term of the requirement shall be imposed. | Class |
904796 | 8908105 | ATLANTIC HERMES | ![]() |
Fishing | CLASS SUSPENDED | New Installed foundations in accordance with Reviewed "Project No. J281/4.488-901-101 КД" (see the letter 122-341-8- 235267 dd 12.08.2019) by branch Office, Lithuania (122) to be submitted for survey. | Class |
906471 | 8670576 | DIMOSTHENIS | ![]() |
Passenger unberthed | CLASS VALID | Next survey in dry-dock is assigned till 08.03.2020 in accordance with PD 175/88 (every two years ship's survey in dry-dock to be carried out by authorities). | Statutory |
910655 | 8908131 | KARELIA | ![]() |
Fishing | CLASS VALID, THE SHIP IS UNDER SURVEY | The 1st deck platings in the following areas: aft - fr. 21 P / S (2, 3, 4 belts from the side), frs. 57-73 P (2, 3 belts from the side), frs. 39-83 S (2, 3 belts from the side) are to be repaired. | Class |
911130 | 8859756 | GORGIPPIYA | ![]() |
Passenger unberthed | CLASS SUSPENDED | The repair of ME ДРА-210В air distributor of tire-pneumatic clutch repair should be perform under RS supervision. | Class |
911130 | 8859756 | GORGIPPIYA | ![]() |
Passenger unberthed | CLASS SUSPENDED | RS Certificates for hydrostatic release units with ser. Nos 126478, 126481 installed with inflatable life rafts are to be submitted. | Statutory |
911130 | 8859756 | GORGIPPIYA | ![]() |
Passenger unberthed | CLASS SUSPENDED | RS Certificates for inflatable liferafts of type "VIKING-20DK'' with ser. Nos. 20DK-R010191, 20 DK-Т060191, 20 DK-R100191, 20 DK-R080191 and type "VIKING-20DK+'' with ser. Nos. 20DK-T050191, 20DK-R050191 are to be submitted. | Statutory |
912824 | 8860200 | MURMANSK | ![]() |
Fishing | CLASS SUSPENDED | Due to the Fleet Monitoring System is applied for the ship, an occasional survey in scope of annual one shall be carried out according to item 4.8.3.1, Part II "Survey Schedule and Scope" of the Rules for the Classification Surveys of Ships in Service". After completion of the survey a new term of the requirement shall be imposed. | Class |
912824 | 8860200 | MURMANSK | ![]() |
Fishing | CLASS SUSPENDED | It is necessary to fulfill RS report No.21.02502.150 dd 19.01.2021 requirements for occasional survey completion before the ship departure but not later than 21.01.2021. | Class |
922629 | 8891924 | TURKMENISTAN | ![]() |
General cargo | CLASS SUSPENDED | To put in working condition Aux. DG № 3. | Class |
922629 | 8891924 | TURKMENISTAN | ![]() |
General cargo | CLASS SUSPENDED | To present Report on examination of ship's safety radio equipment (ф.6.3.22.2) issued by recognition organization. | Statutory |
922629 | 8891924 | TURKMENISTAN | ![]() |
General cargo | CLASS SUSPENDED | To present annual test report of AIS by recognition organization. | Statutory |
922629 | 8891924 | TURKMENISTAN | ![]() |
General cargo | CLASS SUSPENDED | To present annual test report of VDR by recognition organization. | Statutory |
922667 | 8907113 | PETR I | ![]() |
Fishing | CLASS VALID | The ship to be supply with an Ship energy efficiency management plan (SEEMP) Part II. | Statutory |
930593 | 8897497 | MARS | ![]() |
Fire-fighting vessel | CLASS SUSPENDED | Выполнить полный ремонт дублирующих листов в районе настила главной палубы и выгородок в районе 31-37 шп., ПрБ, до даты очередного освидетельствования (05.08.2020). (см. письмо РС No185-343-1-139280 от 22.05.2019). | Class |
930593 | 8897497 | MARS | ![]() |
Fire-fighting vessel | CLASS SUSPENDED | Выполнить полный ремонт дублирующих листов в районе палубы 2-го яруса в районе 30-39 шп. до даты очередного освидетельствования (05.08.2020). (см. письмо РС No185-343-1-325984 от 30.11.2018). | Class |
930593 | 8897497 | MARS | ![]() |
Fire-fighting vessel | CLASS SUSPENDED | Выполнить полный ремонт дублирующих листов главной палубы в районе носового шпиля 5-6 шп. до даты очередного освидетельствования (05.08.2020). (см. письмо РС No185-343-1-119132 от 29.04.2019). | Class |
930593 | 8897497 | MARS | ![]() |
Fire-fighting vessel | CLASS SUSPENDED | Выполнить полный ремонт палубы рубки I яруса в районе 19-23 шп. до даты очередного освидетельствования (05.08.2020). (см. письмо РС No185-343-1-293937 от 07.10.2019). | Class |
930790 | 8935914 | ARKTUR | ![]() |
Fishing | CLASS SUSPENDED | The Report on the results of shafting torsional vibration measurements from a testing laboratory recognized by the RS should be submitted not later than 15.01.2021 | Class |
931539 | 9113276 | BROTHERS-2 | ![]() |
Oil tanker | CLASS VALID, THE SHIP IS UNDER SURVEY | To restore operability of auxiliary boiler and to submit in operation. | Class |
932870 | 9056571 | IMMANUEL | ![]() |
Oil tanker | CLASS VALID, THE SHIP IS UNDER SURVEY | Repair of the deformed plating forecastle deck (PS, frs 143 – 145) should be performed. | Class |
990734 | 9209087 | DISCOVER | ![]() |
Bulk carrier | CLASS VALID, THE SHIP IS UNDER SURVEY | Letters P and С to be permanently marked near plimsol mark. | Statutory |
990823 | 9198094 | BLUE STAR | ![]() |
Oil tanker | CLASS VALID | To submit to RS the Ship Station License m/v "BLUE STAR" RS 990823 till 25.12.2020. | Statutory |
© Russian Maritime Register of Shipping, 2021
Fr: 8:30 – 16:15 (msk)